Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x262B — See Analog 18 / Pin 27 Out of Range
Message on the display: See Analog 18 / Pin 27 Out of Range
Code 0x262B occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
blocking fault
Flash pattern 11-13 (flash code 0xBD).
Description from the Genie service manual, in the original wording.
Effect on the machine: See Analog 1 Out of Range
Possible causes
- See Analog 1 Out of Range
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
What service does
A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x262B not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 0x2628See Analog 9 / Pin 24 Out of Range
- 0x262ASee Analog 14 / Pin 14 Out of Range
- 0x2631Analog Assignment Fault Fault Type(s): 13 X = Analog Input number that caused the fault. {X = 1-9, 14, 18- 19, 31}
- 0x262CSee Analog 19 Out of Range
- 0x2834Pump Current Sensor Fault Sensor zero- current offset close to supply voltage or sensor (supply) ground.
- 0x2860Branding Error