Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2420 — PUMP DRIVER FAULT
Message on the display: PUMP DRIVER FAULT
Code 0x2420 occurs in machines: Genie S-60 DC.
blocking fault
Flash pattern 3-3.
Description from the Genie service manual, in the original wording.
Effect on the machine: The assigned pump-contactor driver is either open or shorted, or exceeded its overcurrent setting 1. Open or short on driver load 2. Dirty connector pins at controller or contactor coil 3. Bad connector crimps or faulty wiring
Possible causes
- Pump Driver Fault Fault Type(s): 1 = Driver Short 2 = Driver Overcurrent 3 = Open/Short (High, should be Low) 4 = Open/Short (Low, should be High) 5 = Open Wire (at pin) 7 = Undercurrent
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
What service does
A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2420 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 0x2871ECC Run Time Error An embedded C application has encountered a runtime error. Fault Type(s)
- 0x2890ERU Configuration Bad configuration for EXISEL in the ERU.
- 0x2891Desat Trip DESAT trip detected. Fault flags(s): 0x01 = U phase. 0x02 = U phase. 0x04 = V phase. 0x08 = V phase. 0x10 = W phase. 0x20 = W phase.
- 0x22A2Interlock Input Conflict
- 0x2880PWM DRIVER COUNT
- 0x2629PWM INPUT 10 OUT OF RANGE