Genie S-85 XC FE and S-85 XC E (hybrid and electric drive)
Genie error code 24-17 — Primary boom angle — Not calibrated
Message on the display: Primary boom angle — Not calibrated
Code 24-17 occurs in machines: Genie S-85 XC FE, S-85 XC E.
blocking fault
The Genie display shows code 24-17 with the message “Primary boom angle — Not calibrated”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.
Effect on the machine: *Primary Boom Up Recovery Sequence: *Until the primary boom is fully retracted Primary Boom Down shall be inhibited.
Possible causes
- Sensor has been replaced and requires calibration. Sensor and magnet not replaced as a matched set
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
* Perform boom angle calibration process and verify fault is no longer active.
Source: Genie Service and Repair Manual S-85 XC FE / E (Part No. 1337498), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.