Genie S-85 XC FE and S-85 XC E (hybrid and electric drive)

Genie error code 24-19 — Primary boom angle — Out of range

Message on the display: Primary boom angle — Out of range

Code 24-19 occurs in machines: Genie S-85 XC FE, S-85 XC E.

blocking fault

The Genie display shows code 24-19 with the message “Primary boom angle — Out of range”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Also Inhibited: Block Primary Up if Off Level (Off Level Restriction) Pump 3 calibration

Possible causes

  • Limit switch LSB3AS indicates stowed, but angle not within 2% of value. Angle is >2% of calibration range. Limit switch LSB3AS indicates stowed and angle sensor indicates value >10° or <7°.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

* With the boom stowed, 26V at TCON pin J2-12 (C68LS BL). * With the boom above 12°, 0V at TCON pin J2-12 (C68LS BL). * Check limit switch LSB3AS for damage. * Check bearings in rotary base housing. * Calibrate angle sensor.

Source: Genie Service and Repair Manual S-85 XC FE / E (Part No. 1337498), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.