609 609 105609 609 104

Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers

Genie error code 0x2103 — Motor Setup Needed Fault Type(s): Hex # Bit1 – 4 Binary 0000 => bits 4 3 2 1

Message on the display: Motor Setup Needed Fault Type(s): Hex # Bit1 – 4 Binary 0000 => bits 4 3 2 1

Code 0x2103 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.

blocking fault

Flash pattern 3-10 (flash code 0x3A).

Description from the Genie service manual, in the original wording.

Effect on the machine: Fault Action: None. Yet, the motor will not operate until the motor configuration and/or commissioning tests are complete.

Possible causes

  • Motor setup is required. Please refer to fault type. Bit1: The current regulator needs to be configured. Bit2: The slip gain test needs to be run. Bit3: The base speed test needs to be run. Bit4: The automated test needs to be run (full motor commissioning).

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Set: Default for both ACIM and PMAC motors. Clear: Run the appropriate motor commissioning sequences.

Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 0x2103 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system