Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers

Genie error code 0x2130 — Severe B+ Overvoltage

Message on the display: Severe B+ Overvoltage

Code 0x2130 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.

blocking fault

Flash pattern 1-8 (flash code 0x18).

Description from the Genie service manual, in the original wording.

Effect on the machine: ShutdownVehicle: ShutdownMotor ShutdownMainContactor ShutdownEMBrake ShutdownThrottle FullBrake ShutdownPump

Possible causes

  • Battery parameters are misadjusted.
  • Battery resistance too high for given regen current.
  • Battery disconnected while regen braking. See Programmer » System Monitor menu » Controller» Capacitor Voltage.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Set: Capacitor bank voltage exceeded the Severe Overvoltage limit with the FET bridge enabled. Clear: Bring capacitor voltage below Severe Overvoltage limit, and then Reset Controller.

Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.