Genie error code 0x2132 — Severe KSI Overvoltage
Message on the display: Severe KSI Overvoltage
Code 0x2132 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
blocking fault
Flash pattern 1-8 (flash code 0x18).
Description from the Genie service manual, in the original wording.
Effect on the machine: ShutdownVehicle: ShutdownMotor ShutdownMainContactor ShutdownEMBrake ShutdownThrottle FullBrake ShutdownPump
Possible causes
- Battery-voltage applied to KSI (pin 1) exceeds the Severe Overvoltage limit. See Programmer » Monitor menu » Battery » Keyswitch Voltage.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: KSI voltage exceeded the Severe Overvoltage limit. Clear: Bring KSI voltage below the Severe Overvoltage limit, and then Reset Controller.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.