609 609 105609 609 104

Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers

Genie error code 0x22A2 — Interlock Input Conflict

Message on the display: Interlock Input Conflict

Code 0x22A2 occurs in machines: Genie S-60 DC.

blocking fault

Flash pattern 7-7.

Description from the Genie service manual, in the original wording.

Effect on the machine: ShutdownVehicle

Possible causes

  • Home switch disconnected, or broken
  • Check wiring to ensure both switches have continuity to controller connector
  • Check if configured correctly for NC/NO

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Clear: Reset Controller

Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 0x22A2 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system