Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2629 — PWM INPUT 10 OUT OF RANGE
Message on the display: PWM INPUT 10 OUT OF RANGE
Code 0x2629 occurs in machines: Genie S-60 DC.
warning / function limited
Flash pattern 12-5.
Description from the Genie service manual, in the original wording.
Effect on the machine: 1. This fault diagnostic execution cycles every 4msec. The input is considered disconnected if no PWM signal occurs for 16msec or the measurements are not updated every 16msec 2. Mistuned parameters 3. Faulty wiring
Possible causes
- PWM Input 10 Out of Range Fault Type(s): 1 = The input is disconnected 2 = The measured input frequency is below the tolerance 3 = The measured input frequency is above the tolerance 4 = The measured duty cycle is below set limits 5 = The measured duty cycle is above set limits
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
None (warning)
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2629 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
