609 609 105609 609 104

Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers

Genie error code 0x2460 — Emergency Reverse High Pedal HPD

Message on the display: Emergency Reverse High Pedal HPD

Code 0x2460 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.

warning / function limited

Flash pattern 4-7 (flash code 0x47).

Description from the Genie service manual, in the original wording.

Effect on the machine: ShutdownThrottle ShutdownEMBrake Dual Drive Same, both motors

Possible causes

  • Emergency Reverse operation has concluded, but the throttle, forward and reverse inputs, and interlock have not been returned to neutral.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Set: At the conclusion of Emergency Reverse, the fault was set because various inputs were not returned to neutral. Clear: If EMR Interlock = On, _ clear the interlock, throttle, and direction inputs. If EMR Interlock = Off, _ clear the throttle and direction inputs.

Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 0x2460 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes