Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2151 — Motor Temp Hot Cutback
Message on the display: Motor Temp Hot Cutback
Code 0x2151 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
warning / function limited
Flash pattern 2-8 (flash code 0x28).
Description from the Genie service manual, in the original wording.
Effect on the machine: Reduced drive torque. If the MotorBrakingThermalCutBa ck Enable = On, then _ Regen Braking Torque is reduced. Fault Action:None, unless a fault action is programmed in VCL.
Possible causes
- Motor temperature is at or above the programmed Temperature Hot setting ― resulting in a reduction of controller drive current.
- The motor temperature and sensor control parameters are misadjusted. See Programmer » AC Motor Setup » Temperature Sensor.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: Motor temperature is at or above the Temperature Hot parameter setting. Clear: Bring the motor temperature within range.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2151 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system