Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2532 — Ext 12V Supply Failure Fault Type(s):
Message on the display: Ext 12V Supply Failure Fault Type(s):
Code 0x2532 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
blocking fault
Flash pattern 2-6 (flash code 0x26). Sub-types: 1 = 12V Supply’s voltage is out-of- range. 2 = 12V Supply’s current is out-of- range.
Description from the Genie service manual, in the original wording.
Effect on the machine: Disables the 12V Supply. Fault Action: None, unless a fault action is programmed in VCL.
Possible causes
- External load impedance on the +12V supply is too low. See Programmer » System Monitor menu » Outputs: External 12V Supply, _ _ Ext 12V Current. _ _
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: (1) The 12V supply (pin 23) is outside 12V ± 15%. (2) The current is outside the limits defined by: Ext 12V Supply Min _ _ _ Ext 12V Supply Max _ _ _ Clear: Reset Controller. Or Reset using the VCL variable Ext 12V Output Enable. _ _ _
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2532 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system